Monogram ZGU385N Manuel du propriétaire Page 17

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 16
JIlnstallat.ionnstructlons I
Convert LP Gas Model ZGU385LSMSS
to Natural Gas Operation
SAFETY INFORMATION
The pressureregulator and burner orifices are set for
Liquid Propane(LP)gas operation.
To convert this cooktop from LPgas operation to
natural gas operation, the regulator and burner orifices
must be converted. Natural gas burner orifices are
attached to the regubtor.
CAUTION- The cooktop, as shipped from the
factorg, is set for use with its intended gas. If gou wish
to use gour cooktop with the alternate gas, gou must
first replace the orifices and convert the pressure
regulator.
-4,WARNING- Thisconversionmustbe
performed /jointfilesconvert/296571/bg a qualified installer or gas supplier in
accordance with the manufacturer's instructions and
all codes and requirements of the authoritg having
jurisdiction. Failure to follow instructions could result in
serious injurg or propertg damage. The qualified agencg
performing this work assumes responsibilitg for the
conversion.
CAUTI0 N - Thefollowing adjustments must
be made before turning on the burner. Failure to do so
could result in serious injurg. Besure pressure regulator
has been converted as described in Step 1.
TOOLS YOU WILL NEED FOR
CONVERSION
Crescent wrench
7mm nutdriver
Safety glasses
Small flat-head
screwdriver
(2 to 2.4 mm or
3/32" tip size,
60 mm long)
[1] ADJUST THE REGULATOR
A. Disconnect all electrical power,at the main circuit
breaker or fuse box.
B. Shut offthe gas supplu to the cooktop /jointfilesconvert/296571/bg closing the
manual shut-off valve.
C. Adjustthe pressureregulator /jointfilesconvert/296571/bg the following
instructions:
Unscrewthe cap.
Placeyour thumb against the flat side of the spring
retainer and pressdown to removethe retainer.
Carefullylook at the spring retainer to locate the NAT
or LPposition.
Cap Gasket
__/_ Spring
NAT _**[.____"" ""_L p_,prroe_:iner
position _ _ ..........................:_'..L position
Pressure regulator
Turn the spring retainer over so that the desired gas is
showing on the bottom.
Snap the retainer buck into position.
Screwthe cap beck onto the regulator.
[2] CHANGE BURNER ORIFICES
INSTALLATIONTIP: Firstremove all Burner cap
orifices and then start replacing them.
This will helpto prevent the possibility
that some may not be replaced.
Burner ._
A. Removethe burner grates, (,_
burner caps and burner heads, head
B. Using a 7mm nut driver,remove the __n
top burner orifices.There are two
orifices per burner.
The main orifice is er
located low in the center Spark igniter base
of the burner,while the Simmer
simmer orifice is located orifice __j_ Mainhigher besidethe center z_ '" " "
orifice
of the burner. (__°°_ _ ,
17
Vue de la page 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 35 36

Commentaires sur ces manuels