Monogram WX08X10025 Manuel du propriétaire Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Advance Planning
Design Infi)rmation
36" Stai*_le,s,_ Steel R_fi'ig'erator,s, t;reezer,s
Flush or
Semi-Flush
Enclosure
Installations
True FlushInstallation
In a flush installation,
the refrigerator door
will align evenly with the front
face of adjacent cabinet doors.
The refrigerator blends into the
surrounding cabinetry.
Monogram built-in refrigerators and freezers can be
installed flush with typical 24-3/4"deep cabinetry.
When installed semi-flush, the case trim will conceal
slight gaps around the enclosure. The refrigerator will
project forward approximately 3/4" beyond the front
face of surrounding cabinetry.
Semi-Flush Installation
These refrigerators
can also be installed
semi-flush into an enclosure
using the minimum cutout
width. The case trim creates a
frame around the opening.
Side Panel Requirements:
Side panels are not required whenever the
refrigerator or freezer is installed into an enclosure
or between pantry and oven cabinets.
Side panels are required whenever the sides of the
product are exposed.
Side panel sizes vary depending on the type of
installation being made.
To accomplish an attractive installation, you must:
1. Determine the need for side panels.
2. Determine side panel thickness.
3. Order matching side panels from the cabinet
manufacturer. Be sure to provide the exact dimensions.
Enclosure
Cutout and
Product
Dimensions
To achieve a flush fit, the finished cutout width must be
at least 36" wide.
In a semi-flush installation, the finished cutout must be
35-1/2".
The electrical and water locations must be located
as shown for either type of installation.
35" 24-3/4"
Case _Case
_ Width|Depth
2G3/4"_36" Frame to
Including
Tubular
Handles
84 .+_
Frame
_Shipped at 84" installation height.
Can be adjusted to 83-1/2"
or 84-1/2" with grille panel kits.
_r _Finish_ Width
'I_ _/_ Electrical
_5,,_6,, Area
841/2" max - 24 3/4" Total
83 1/2" rain Depth
Finished
Opening
31/2"
WallView
75" FromFloor
to Bottom
of Electrical
Area
'36" for a flush installation.
35-1/2" Min. for a semi-flush installation.
NOTE:Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width. See installation examples
on the following page.
Vue de la page 2
1 2 3 4 5 6 7 8 ... 19 20

Commentaires sur ces manuels

Pas de commentaire